From the start menu select CHARGE, then select LEAD ACID, then select CA / CA.
Once you have selected this mode your lead acid battery will run through the normal charge profile but will include the Recond mode (stage 6) at up to 15.8 volts which will help de-sulphate a battery with heavy sulphation in an attempt to rejuvenate the battery.